TEKLA & STEEL DETAILING INTERVIEW SIX QUESTIONS

 1.WHICH TYPE OF CONNECTION TO BE PREFERABLE IN FIELD TO REDUCE COST?

   BOLTED CONNECTION IS PREFERABLE WHEN COMPARED TO FIELD WELDING.

*.FIELD WELD IS SO COSTLY THAN FIELD BOLTING.


2.PLEASE DRAW COLUMN WITH BASE PLATE CONNECTION?

JUST FOR REFERENCE

COLUMN WITH BASE PLATE

1.       Bottom of base plate elevation.

2.       Orientation mark of the column.

3.       Column to base plate weld.

4.       Locations of the holes in base plate with respect to the column center line.

5.       Hole diameter and number of holes in base plate.

6.       Base plate thickness.


3.WHAT IS THE HOLE SIZE IN BASEPLATE FOR 3/4 DIA TO 2 1/2 DIA ANCHOR RODS?

 

Size of Anchor – Rod Holes In Base Plates

 

Anchor Rod Dia

 

Max. Hole Dia

 As per LRFD

Hole Dia

 As per ASD

 

 3/4

1 5/16

1  1/16

 7/8

1 9/16

1  3/16

1   

1 13/16

1  1/2

1 1/4

2 1/16   

1 3/4

1 1/2

2  5/16

2

1 3/4

2 3/4

2 1/4

2   

3 1/4

3

2 1/2

3 3/4

3 1/2

Larger holes are permitted if Plate Washers Used.


4.WHAT IS THE USE OF LEVELLING PLATE?

Normally thickness of leveling plate will be ¼ -in. The  leveling plate may be larger than the base plate to accommodate tolerance of Anchor Rod placement.

5.WHAT IS THE USE OF PLATE WASHER?

 The oversize holes should be covered with a heavy plate washer. The minimum thickness should  be one-third the diameter of the anchor rod

  6.WHAT IS THE GRABRAIL EXTENSION FROM LAST TREAD ?

1'-0