Steel detailing Question paper -11

 1.What is the full form of SEOR AND JBE?

SEOR: Senior Engineer of record.

JBE: Joist Bearing Elevation.


2.If Slab thickness 8" but embed plate size is 9" ,what to do?

SOL: We need to accommodate embed plate only in side the concrete if it is projecting out of slab

  then we need to reduce the Size of embed plate to match with the slab thickness.


3.If we have dimensions for operable partition in design drawings,Will you release drawings for 

  Fabrication?

NO,Without receiving final partiton drawings set don't release drawings for fabrication.


4.If members are getting field weld then what to take care in Shop Drawings?

We need to give no paint hatching for members where its get field weld,Also we need to give 2" extra hatching


5.While placing a grid ,What are main step you need to take care?

We need to compare grid dimensions between structural drawings and Arch drawings,If dimensions are  mismatching then we need to raise  RFI .


6..What is the Size of long slotted hole for 1" and 1.5" dia bolt?

For 1"-1 1/16x2 1/2

        1"1/2-1 9/16x3 3/4


7.If suppose W member workable gage 2 "1/4  but design drawings shows to 3/4" bolt ,Is it workable?

No,

1.If we follow  3/4"dia bolt  then bolt will enter in to the encroachment.

2.There will be an edge distance problem. 

So we need to reduce the bolt size to 1/2 dia then we need to take confirmation from client.


8.What is Backgouging?

It is a method of chipping out and filling of the weld on the farside of CJP.




9.Derive E70XX?

E-Electrode.
70-Tensile Strength.
X-Weld position.
X-Electric current used.


10.What are the components of handrail?

1.Top rail
2.Midrail
3.handrail post.
4.Toe plate or angle.


  

Sunday, November 7, 2021

Estimator of structural steel

Anyone need estimation of projects feel free to contact me -tekladetailer2907@gmail.com.

Wednesday, September 29, 2021

While checking anchor bolts,what are the important points to be taken care?

      1.Bottom Of Base plate elevation to be finalized from design drawings


       2.If we use plate washers ,We need to follow over sized holes in base plate i.e 
          for example: if we use 3/4" Ø anchor rod,Hole dia should be 1 5/16"Ø.

      3.Plate washers sizes should be followed for AISC 14.2 table.
         for 3/4"Ø anchor rod , we will follow plate washer size as 1/4"X2X0'-2".

     4.Plate washers is used to cover the over sized holes.

     5.If design drawing does not furnish levelling method pattern then we need send to
         rfi on levelling method,Mostly we will use levelling nut or levelling plate  arrangement.

         we will use levelling plate thickness as 1/4" and we will match plate parameters  to base plate size.

    6. Template : Template is used to match accurate position of anchor rods,Generally
       Template thickness we will follow as 1/8" and we will match length and width as  base plate  size.

    7.Grout hole: If smaller side dimension of the base plate exceeds approximately 2'-0 then we will provide grout hole in base plate.

    8.column schedule to be referred properly ,So that we will exact base plate sizes and  anchor rod dia.

   9.if design drawing does not provide embedment  then we need to calculate embedment 
    by using formula  i.e 12 X Diameter of anchor rod.
   if we use 3/4"Ø then embedment is 9".


  10.If design drawing does not provide projection then we need to calculate projection by 
     using  formula i.e Grout thickness + base plate thickeness + 2 times of anchor rod dia  
      +washer thickness + nut thickness.


  11.We need to identify footing depths properly because we should maintain 3"clearence 
     between bottom of anchor rod and bottom of footing.
     some times in order to maintain footing depth ,We need to deviate embedment values 
     and also we need to ask question for confirmation.


      


 

Friday, August 27, 2021

AUTOCAD BASICS INTERVIEW QUESTIONS

 AUTOCAD BASIC  INTERVIEW QUESTIONS


1.WHAT IS AUTOCAD?

Autocad is  a  computer  aided  designing software which is use  for 2D and  3d  designing  and detailing .

Autocad  is  developed by Autodesk. 


2.WHAT ARE  THE  ADVANTAGES OF AUTOCAD?

  • Provides accurate drawing.
  • spares time and build the  efficiency .
  • We  can provide quality  drawings  with  decorated  hatches.
  • 3D models can be done  for  representation.
  • Modifications can  be done easily.
3.WHAT ARE THE FILE FORMATS USED  IN AUTOCAD?

  • DWG file format used in Autocad.
4.WHAT IS  TEMPLATE  IN AUTOCAD AND ITS USES?

       Template is a file which specifies the styles ,settings,and layout include the title blocks.

5.WHAT IS UI IN AUTOCAD?

UI is a Autocad interface which provides access to most of the commonly used tools.

UI includes the menu bar ,quick access toolbar, command prompt,status bar,The Ribbion.

6.WHAT IS THE LAYERS IN AUTOCAD AND ITS USES?

Layer is a object management system by which we can separate the object's in a drawing according
to their functions.  

For example creating a wall in a different layer and for door also separate layer is required.

Layers are used to control the visibility of objects and assign properties such as color and line type.

7.WHAT IS WORKSPACE IN AUTOCAD AND HOW MANY WORK SPACES ARE AVAILABLE
   IN AUTOCAD?

Work spaces are set of user interface components such as ribbon tabs and pannels , toolbars, palettes
and menu bars ,that are grouped and organized.

There are currently 3 default work spaces available in autocad .In older versions there are 4 work
spaces available include 'classic work space'

1.3D MODELLING
2.3D BASICS 
3.DRAFTING  AND  ANNOTATION.

8.WHICH ARE THE DIFFERENT  TOOLBARS AVAILABLE IN AUTOCAD?

There are many tool bars available in autocad,some important toolbars are  

Draw toolbar, modify toolbar,Dimension toolbar, Layers toolbar ,standard toolbar, Properties tool bar.

9.WHAT IS A COMMAND LINE IN  AUTOCAD ?

Autocad command line is like a combined control panels and index of all autocad you run and have run on your drawing.

It shows which command is currently running and its guides you.

10.WHAT IS THE  USE  OF FILTER IN  AUTOCAD?

Filter is a selection method by which  we  we can select a specified set of objects from drawing.

11.HOW MANY  TYPES OF COORDINATE  SYSTEM  COMMONLY  USED  IN AUTOCAD?

  • Absolute (x,y)
  • Relative (@x,y)
  • Polar(@D<A)
12.WHAT IS THE DIFFERENCE BETWEEN DRAWING,DESIGN  AND DETAILING?

Drawing:Its a rough  sketch of  any product.
Design:Presentation of views (2-D,3-D)without any dimensions.
Detailing:2-D presentation of 3-D Object with proper dimensions.

13.WHAT IS TOLERANCE IN ENGINEERING?

In engineering tolerance is the permissible limits of variation in physical measurement.

14.WHAT IS THE SHORTCUT COMMAND TO CHANGE UNIT IN AUTOCAD?

UN

15.WHICH TYPE OF LINE HAVING INFINITY  LENGTH?

construction line.

16.WHICH COMMAND HAVING TWO SHORTCUT IN AUTOCAD?

COPY:CO,CP

17.WHAT IS THE PAPER SIZE OF A0 AND A3?

A0-841X1129
A3-297X420


                                                                                         


Wednesday, June 23, 2021

Tekla/steel detailing Question paper-10

                       
1).What are the three grade identification colors for ASTM F1554 anchor rods?

F1554-GR.36_BLUE IN COLOUR.
F1554-GR.55_YELLOW IN COLOUR.
F1554-GR.55_RED IN COLOUR.


2).When columns do not have enough local strength, what type of reinforcing
is required to reinforce for web panel-zone shear at a moment connection?

EITHER DOUBLER PLATES OR DIAGONAL STIFFENERS



3.What material type is commonly used for rolled floor plate?

ASTM A786  IS THE MOST COMMONLY USED ROLLED
FLOOR PLATE.



4.Why are fillet welds preferred over groove welds?

Fillet welds generally require less weld metal than groove welds. Additionally, fillet welds do
not generally require beveling and similar base metal preparation. As a result, fillet welds are
generally more economical to make than groove welds. Thus, fillet welds are preferred.



5.Draw Flare Bevel Weld Symbol & Its Condition?

FLARE WELD IS MOST COMMONLY USED TO JOIN  A ROUND OR CURVED PIECE TO
    A FLAT PIECE.


6.Full form of SEOR and GOL?

SEOR_STRUCTURAL ENGINEER OF RECORD.
GOL_GAUGE ON LEG.


7.What is the material grade for twist of type bolts?
 
ASTM F1852 .


8.Please write down the types of beam?

1.sloped beam
2.skwed beam
3.curved beam
4.canted beam
5.hip and valley beam.


9.what is the distance between  hoop to hoop distance in ladder?

4'-0.


10.what is masonry?

The part of building that are made of stone or brick.










Thursday, June 17, 2021

Tekla TEST question paper-9_

1.     High-strength bolts used for the vast majority of field connections are furnished in what two grades?

 A325

A490 

2. The spacing between bolts in standard bolted connections is usually?

3"

3. Currently, the two primary methods of fastening together the major components of a steel-frame structure are BOLTING________and ____WELDING______


4.What angle length is required for a 5-row bolted connection?

1'-3"

5.    Give standard Slot size of 1” dia bolt?

1 1/6"X1"5/16

6.Distance between floor to floor landings is called?

FLIGHT

7    .Maximum column length without splice………. Ft.?

40'-0"

8.What is abbreviation for RFI?

Request for information.

9.  What depth scale is usually used for most steel columns?

12

10.FULL FORM OF BOD,FOW AND JBE?

BOD:BOTTOM OF DECK

FOW:FACE OF WALL

JBE:JOIST BEARING ELEVATION.

1111.When drawing a fillet weld symbol, the size of the fillet weld is always Called out on which side of the symbol?                                                                                                      LEFT SIDE OF THE SYMBOL.

1112 As a detailer what care you need to take if you have SC bolts in a connection?               OVERSIZED HOLES  TO BE PROVIDED                                                                             NO PAINT 3" AROUND HOLES



O







L




4 

Tuesday, June 15, 2021

Tekla interview Question-8

 1.FULL FORM OF ABM ,B.O.BP AND T.O.G?

ABM:ADVANCE BILL OF MATERIALS.

BOBP:BOTTOM OF BASE PLATE.

T.O.G:TOP OF GRATING.

2.WHY  SLOTTED HOLES PROVIDED  IN STEEL MEMBER?

FOR FIELD ADJUSTMENT WE NEED TO PROVIDED SLOTS IN STEEL MEMBER.

ALSO PLEASE NOTE ,LONG SLOTTED HOLES TO BE PROVIDED AT EXISTING CONDITIONS FOR ERECTION FEASABILITY.


3.PLEASE DRAW BEAM RUNNING OVER COLUMN WITH STIFFENERS IN BEAM WEB?


STIFFENERS IS USED TO WITHSTANDS LOADS AND ALSO USED TO TRANSFER LOADS


4.WHAT IS THE TOLERANCES FOR OVERSIZED HOLE AND STANDARD HOLE?

FOR OVERSIZED HOLE-3/16

FOR STANDARD HOLE-1/16

5.WHAT ARE THE MAIN REPORTS NEED TO SEND FOR FABRICATION WHILE SENDING DRAWINGS?

1.DXF

2.NC FILES

3.KISS LIST

4.FABTROL REPORTS

5.BOLT REPORTS

6.DWG FILES

7.TRANSMITTAL.


6.WHAT IS GALVANIZATION AND WHAT IS THE SURFACE PREPARATION FOR GALVANIZED MEMBER?

GALVANIZATION:PROCESS OF ADDING ZINC COATING TO THE METAL TO AVOID CORROSSION.

ASTMA123 IS THE SURFACE PREPARATION FOR GALVANIZED MEMBER


7.WHAT IS THE STOCK LENGTH FOR PLATES ,ANGLES AND BENT PLATES?

ANGLE-20'-0

BENT PLATE-10'-0

PLATE-10'-0.


8.WHAT IS ENCROACHMENT?

THE PERMISSIBLE DISTANCE BEYOND THE WORKABLE GAGE OR THE LIMITED DISTANCE TO ENTER IN TO FILLET OR ROUNDING RADIUS.

GENERALLY TERMED AS "K" VALUE.

?

9.HOW TO FIX WORKPOINTS IN BRACING ?

WORKPOINT PASSES THROUGH THE GAUGE LINE IN CASE OF BOLTING.
WORKPOINT PASSES THROUGH CENTRE OF GRAVITY IN CASE OF WELDING

10.DERVIE E70XX?


E-ELECTRODE

7-TENSILE STRENGTH

X-WELD POSITION

X-ELECTIC CURRENT USED


11.IF HSS COLUMN AND HSS BEAM ARE DIRECTLY WELDING IN FIELD THEN WHAT IS THE MAIN THING REQUIRE FOR FIELD WELDING?

ERECTION AID-(Angle)


12.WHAT IS THE WIDTH OF LADDER AND MAXIMUM LENGTH  OF A LADDER?

WIDTH-1'-6"

LENGTH-20'-0


13.WHEN SEISMIC LOADS WILL FORM?

THE LOADS WHICH ARE FORMED BY SUDDEN VIBRATIONS IS KNOWNS AS SEISMIC LOADS.

GENERALLY SEISMIC LOADS ALSO KNOWN AS EARTHQUAKE LOADS.


14.WHAT IS A POST?

IF WEIGHT IS LESS THAN 300LBS AS PER OSHA THEN WE CALL IT AS POST.

IF WEIGHT IS MORE THAN 300LBS THEN IT WILL BE COLUMN.


15.WHAT ARE THE MAIN FACTORS TO DESIGN A CONNECTION BETWEEN BEAM TO BEAM?

NORMALLY CONNECION DESIGNER WILL DESIGN THE CONNECTION BASED ON LOADS(KIPS)

BASED ON STRUCTURAL ENGINEER REQUIREMENTS.





Wednesday, June 9, 2021

TEKLA & STEEL DETAILING QUESTIONS INTERVIEW-7

 1.FULL FORM OF NISD AND HVAC?

NISD:NATIONAL INSITITUTE OF STEEL DETAILING.

HVAC:HEAT VENTILATION AND AIR CONDITIONING


2.WHAT IS THE SHORTCUT  TO OPEN DRAWING LIST IN TEKLA?

MODELER EDITOR:CTRL+L

DRAWING EDITOR: CTRL+O


3.MENTION SOME CONDITIONS WHERE ALL AROUND FILET WELD APPLICABLEDE?

1.BASE PLATE & COLUMN

2. BEAM &END PLATE 

3. CAP PLATE & COLUMN


4.IF DESIGN DRAWING DOES NOT FURNISH WELD SIZE THEN  HOW TO DETERMINE WELD SIZE BETWEEN TWO MEMBERS ?

WELD SIZE  TO BE CONSIDER BASED ON  THE LOWEST THICKNESS BETWEEN TWO MEMBERS 


5.DERIVE BU4-GF?

B-BUTT WELD

U-UNLIMITED BASE METAL THICKNESS

4-SINGLE BEVEL

GF-WELDING PROCESS


6.HOW TO FIX RUNGS IN LADDER ?

FIRST WE NEED TO FIX TOP OF RUNG EQUAL TO  TOP OF FINISIED LEVEL OR TOP OF GRATING  THEN WE NEED TO SPACE THE RUNGS.

GENERALLY RUNG TO RUNG SPACING SHOULD BE 1-0


7.WHAT IS THE OVERHEAD CLEARENCE BETWEEN STAIR AND FLOOR AS PER OSHA?

6'-8" TO BE MAINTAINED


8.WHAT IS THE RULE BETWEEN STRINGER WIDTH AND LANDING CLEARENCE ?

LANDING  CLEARENCE SHOULD BE MORE THAN THE STRINGER WIDTH.THIS A GENERAL PRACTICE TO DETAIL STAIR LANDING


9.WHAT IS THE MAX TREAD AND RISER DIMENSION  IN  STAIR?

RISER SHOULD BE  MAX 7"
TREAD SHOULD BE  MAX 11"

10.WHAT IS THE MAXIMUM SPACING TO BE MAINTAINED  BETWEEN POST TO POST AND PICKET TO PICKET?

POST TO POST-4'-0
PICKET TO PICKET-4"

11.HANDRAIL HEIGHT TO BE FIXED FROM?

NOSING LINE OR TOP OF FINISHED FLOOR.


12.DEFINE NOSING LINE?

THE LINE WHICH TOUCHES ALL NOSING POINTS IS KNOWN AS NOSING LINE

NOSING POINT: INTERSECTION OF PAN TREAD AND RISER 


13.HOW TO CONNECT WALL RAIL TO WALL?

CONNECTION BETWEEN WALL AND WALL RAIL  BY USING WALL BRACKET .

GENERALLY WALL BRACKET IS A BOUGHT ITEM.


14.WHAT IS THE ANGLE  TO DETAIL STAIR AS PER OSHA?

STAIR ANGLE SHOULD BE  30 DEGREE TO 50 DEGREE TO DETAIL STAIR.











Monday, May 24, 2021

TEKLA INTERVIEW QUESTION PAPER-6

1.WHAT IS THE FULL FORM OF AWS AND LRFD?

AWS:AMERICAN WELDING SOCIETY.

LRFD: LOAD RESISTANCE FACTORY DESIGN.

2.WHAT ARE THE INPUT DRAWINGS OF STEEL DETAILING?

1.STRUCTURAL DRAWING

2.ARCHITECTURAL DRAWING

3.CIVIL DRAWINGS.

4.DECK DRAWINGS

5.JOIST DRAWINGS

6.ELEVATOR DRAWINGS

3.WHAT IS THE FLANGE GAGE FOR W8X31 COLUMN OR BEAM?

4"

4.DEFINE BACK CHARGE?

COSTS DIRECTED TO A FABRICTOR OR STEEL DETAILER FOR ERRORS IN FABRICATION OR DETAILNG.

5.WHAT IS MEANT BY SQ2E , SQ1E AND BEV?

SQ2E:SQUARE CUT BOTH ENDS

SQ1E:SQUARE CUT ONE END

BEV:BEVEL

THIS TERMS USUALLY WILL MENTION IN DRAWING BOM

6.WHAT ARE THE TYPES OF DECK?

1.COMPOSITE FLOOR DECK

2.ROOF DECK.

3.CELLULAR DECK.

4.FORM DECK.

7.WHAT IS THE USE TOE PLATE AND RUNGS?

TOE PLATE:

IS A SAFETY FEATURE IN HANDRAILS TO AVOID THE ACCIDENTS DUE TO SLIPPING OF FOOT.

RUNG:

RUNGS ARE STEPS IN LADDER TO ACCESS THE PLATFORM OR FLOOR


8.WHAT IS GRADE FOR REBAR ?

NORMAL GRADE IS ASTM A706 GRADE-60

IF IT IS WELDED THEN ASTM A615


9.IN W16X40 WHAT IS 16 AND WHAT IS 40?

16-IS NOMINAL DEPTH

40 IS LBS/FEET

10.WHAT IS THE CLEARENCE BETWEEN WALL TO HANDRAIL OR WALL RAIL?

CLEARENCE IS 1 1/2"


11.WHAT IS THE USE OF BACK UP BAR?

IN ORDER TO AVOID THE OVERFLOW OF WELD.


12.WHAT ARE THE TEMPORARY BOLTS AND WHAT ARE THE HIGH STRENGTH BOLTS?

A307 BOLTS ARE TEMPORARY  WHEREAS A325 AND A490 ARE HIGH STRENGTH BOLTS.


13.IF ONE BEAM IS STRAIGHT AND OTHER BEAM IS SKEWED THEN WHAT KIND OF 

CONNECTION WE NEED TO PROVIDE?

BENT PLATE CONNECTION WE NEED TO USE


14.WHAT IS ASTMA325T BOLT?

BOLT IS FULLY THREADED UP TO FULL LENGTH OF SHANK.


15.WHAT IS THE MAXIMUM AVAILABLITY LENGTH FOR A BOLT?

 MAXIMUM LENGTH AVAILABLITY FOR A BOLT IS 8" ,IF IT IS MORE THAN 8" THEN

WE NEED USE ROD.

Monday, May 17, 2021

OSHA REQUIREMENTS AND RULES

 

 OSHA REQUIREMENTS


BASE PLATE :

  • BASEPLATE NEED TO HAVE MINIMUM 4 ANCHOR BOLTSA

  • USAGE OF LEVELING NUT OR LEVELING PLATE SHOULD BE DISCUSSED WITH ERECTOR

  • DETAILER SHOULD REFER TO DESIGN DRAWINGS TO PROVIDE OVERSIZED HOLES IN BASE PLATE ,IF INFORMATION MISSING THEN WE NEED TO REFER TABLE C-J9.1 AND 14.2 OF AISC BOOK.

COLUMN
  • COLUMN SPLICE SHOULD BE AT 4'-0 FROM FINISHED FLOOR 

 

  •  ALL PERIMETER COLUMNS SHOULD HAVE SAFETY HOLES FOR WIRE GUARD RAIL ONE AT 1'-9 FROM FINISHED FLOOR AND SECOND AT 3'-6 FROM FINISHED FLOOR

 

  •  ALL COLUMNS SHOULD BE PROVIDED WITH LIFTING HOLE SPECIALLY TIER COLUMNS,NORMALLY LIFTING HOLE DIA IS 2'-0.

 

  •     ALL COLUMNS SHOULD HAVE CORRECT ORIENTATION MARK TO ERECT THE COLUMN.


    • EXTENDED SHEAR TAB CONNECTION TO BE FOLLOWED WHERE BOLT ACCESS IS BLOCKED BY FLANGES.       

BEAM:

  • MINIMUM OF TWO BOLTS REQUIRED AT EACH END OF BEAM FOR ERECTIO

  • D/2 RULE TO BE SATISFIED AT EACH CONNECTION TO SATISFY REQUIRED LOADS

  • ALL DOUBLE ANGLE CONNECTIONS AT COLUMN WEB OR BEAM WEBMUST HAVE STAGGERED CLIP ANGLES OR A BEAM SEAT  OR A TOP FLANGE CLIP ANGLE .WHEN NOT POSSIBLE TO PROVIDE SAFETY CONNECTIONS THE DETAILER SHOULD ADD A NOTE OF WARNING  TO THE ERECTOR ON EPLANS.


JOISTS:

  • IF JOIST SPAN  MORE THAN 40'-0  THEN WE SHOULD BE PROVIDED WITH 2 ERECTION BOLTS

  • VERTICAL STABILZER PLATE NEED TO BE PROVIDED, THIS PLATE SHOULD BE OF MINIMUM 6"X6"  AND 3" BELOW THE BOTTOM OF JOIST, WITH 13/16DIA HOLE FOR GUYING OR PLUMBING CABLES.

DECK :

  • DECK SUPPORT MAY BE REQUIRED AT DECK CUTOUTS NEAR BEAM TO BEAM OR BEAM TO COLUMN CONNECTIONS,REFER DESIGN DRAWING OR THE CLENT FOR PREFERRED METHOD

SNAGGING HAZARDS:

  • AVOID SHARP CORNERS.
 
CONNECTIONS:

  • USE BEARING CONNECTIONS AND AVOID HANGING CONNECTIONS.

TRIPPING HAZARDS:

  • ANY CONNECTIONS OR OBSTRUCTIONS SHOULD BE AVOIDED ON TOP OF BEAM OR JOIST.


FALL PROTECTION:

  • MULTISTORAGE STRUCTURE REQUIRES GUARD RAIL CABLES AT FLOOR PERIMETER ,INTERIOR OPENINGS  AND ROOF OPENINGS.THIS PROTECTION SUPPORT SHOULD BE AGREED UPON PRIOR TO COMENCEMENT OF DETAILING.

ERECTION AID:

  • FOR FIELD WELDS OF TUBES OR BRACINGS ,WE NEED TO PROVIDE ERECTION BOLT OR ERECTION ANGLE FOR SUPPORT

Saturday, May 15, 2021

WHAT IS TEKLA & STEEL DETAILING?

TEKLA means building inormation modelling software used in building and construction industries for steel,concrete and precast detailng.

Types of versions in tekla.

17.0,
17.1,
18.0,
18.1,
19.0,
19.1,
20.0,
20.1,
21.0,
21.1.
TEKLA 2017,TEKLA 2018,TEKLA 2019,TEKLA 2020.

WHAT ARE THE ENVIORNMENTS IN TEKLA?

US IMPERIAL,US METRIC,UK,INDIAN.

FOR US WE WILL USE US IMPERIAL.

WHAT ARE THR ROLES IN TEKLA?

 STEEL DETAILING
 CASTING,
ENGINEERING

WHO WILL DO PROJECT IN TEKLA ?

DETAILER,
MODELER
CHECKER

STEEL DETAILNG?

THE PROCESS OF CONVERTING DESIGN DRAWING IN TO  SHOP & FIELD DRAWINGS IS KNOWN AS STEEL DETAILING.

 HOW PROCESS WILL START?



What are the responsblies of detailer?

1.HE NEED TO EDIT SHOP DRAWINGS & ERECTION DRAWINGS WITH RESPECTIVE TO DESIGN DRAWINGS IN AN UNDERSTANDING MANNER.

what are the responsiblies of modeler?

HE NEED TO CONSTRUCT THE BUILDING IN 3D VIEW WITH RESPECTIVE 
TO DESIGN DRAWINGS IN AN UNDERSTANDING MANNER.

What are the responsibilities of checker?

He need to check and correct the errors of detailer and modeler with respective to design drawings.

He need to coordinate with detailer and modeler to achieve desired output.


*************************************************************************PLEASE MENTION YOURS COMMENTS AND SUPPORT ME FOR FURTHER
UPDATES.

Thursday, May 13, 2021

MOMENT SPLICE CONNECTIONS (STEEL DETAILING & TEKLA)

 1.DRAW FLANGE PLATED SPLICE MOMENT CONNECTIONS?


                                  FLANGE PLATED SPLICE MOMENT CONNECTIONS.

 

DIRECTLY WELDED MOMENT SPLICE CONNECTION



Wednesday, May 12, 2021

TEKLA & STEEL DETAILING INTERVIEW SIX QUESTIONS

 1.WHICH TYPE OF CONNECTION TO BE PREFERABLE IN FIELD TO REDUCE COST?

   BOLTED CONNECTION IS PREFERABLE WHEN COMPARED TO FIELD WELDING.

*.FIELD WELD IS SO COSTLY THAN FIELD BOLTING.


2.PLEASE DRAW COLUMN WITH BASE PLATE CONNECTION?

JUST FOR REFERENCE

COLUMN WITH BASE PLATE

1.       Bottom of base plate elevation.

2.       Orientation mark of the column.

3.       Column to base plate weld.

4.       Locations of the holes in base plate with respect to the column center line.

5.       Hole diameter and number of holes in base plate.

6.       Base plate thickness.


3.WHAT IS THE HOLE SIZE IN BASEPLATE FOR 3/4 DIA TO 2 1/2 DIA ANCHOR RODS?

 

Size of Anchor – Rod Holes In Base Plates

 

Anchor Rod Dia

 

Max. Hole Dia

 As per LRFD

Hole Dia

 As per ASD

 

 3/4

1 5/16

1  1/16

 7/8

1 9/16

1  3/16

1   

1 13/16

1  1/2

1 1/4

2 1/16   

1 3/4

1 1/2

2  5/16

2

1 3/4

2 3/4

2 1/4

2   

3 1/4

3

2 1/2

3 3/4

3 1/2

Larger holes are permitted if Plate Washers Used.


4.WHAT IS THE USE OF LEVELLING PLATE?

Normally thickness of leveling plate will be ¼ -in. The  leveling plate may be larger than the base plate to accommodate tolerance of Anchor Rod placement.

5.WHAT IS THE USE OF PLATE WASHER?

 The oversize holes should be covered with a heavy plate washer. The minimum thickness should  be one-third the diameter of the anchor rod

  6.WHAT IS THE GRABRAIL EXTENSION FROM LAST TREAD ?

1'-0

 

 

Tuesday, May 11, 2021

CONNECTIONS SKETCHES-STEEL DETAILING -USEFUL POST.

 1.PLEASE DRAW DOUBLE ANGLE CONNECTIONS ?


CLIP ANGLE CONNECTIONS



2.PLEASE DRAW SHEAR PLATE CONNECTION?

END PLATE CONNECTION
SHEAR PLATE CONNECTION.
                           EXTENDED SHEAR TAB CONNECTION                                                                                                 
                                                                                                                                                   3.PLEASE DRAW T JOINT CONNECTIONS ?



T-JOINT CONNECTION
4.DRAW SINGLE ANGLE CONNECTIONS?

5.DRAW COLUMN FLANGE MOMENT BOLTED CONNECTION?


6.DRAW COLUMN WEB MOMENT  BOLTED CONNECTION?



7.DRAW COLUMN FLANGE MOMENT WELDED CONNECTION?



8.DRAW COLUMN WEB MOMENT WELDED CONNECTION?


















 








                                                                                                                                                  



Featured Post

WHAT IS TEKLA & STEEL DETAILING?

TEKLA means building inormation modelling software used in building and construction industries for steel,concrete and precast detailng . Ty...